Philips Hf-p 158 tl-d iii 220-240v 50/60hz idc
An energy-efficient solutionHF-Performer III TL-D is a slim and high-frequency electronic ballast for TL-D fluorescent lamps. It is ideal for applications where high energy efficiency is required. The HF-Performer III range has a robust design, meets all relevant international safety and performance standards and is energy-efficient (CELMA EEI A2 BAT). Product Features • Robust design for 100,000 hours lifetime at Ta = 50 C and over 100,000 on/off switching operations on one lamp • Programmed, flicker-free, pre-heated start (< 0.5 s) which allows the lamp to be switched on and off without reducing useful lamp life • Active power factor correction to ensure constant light, irrespective of mains-voltage fluctuations • The unit is protected against excessive mains voltage and incorrect connections. Product Benefits • The programmed start enables the lamp to be switched on and off without reducing useful lamp life. • DC emergency operation in line with IEC/EN 60598-22 luminaire norms • Smart power ensures constant light, irrespective of mains-voltage fluctuations • Suitable for luminaires in protection class I and, after testing, class II • The universal connector Wago 251 offers the flexibility for horizontal-manual or push-in robot wiring or vertical ALF-robot wiring. Application • Used with movement-detection control systems like Philips OccuPlus • Indoor applications, such as office buildings, hospitals, supermarkets, department stores, industrial premises and schools • Class I outdoor applications, e. g. industrial premises and parking lots
UTVIDET JULERETURRETT FRAM TIL 31. JANUAR 2025
Proshop tilbyr utvidet Juleretur til privatkunder på ordre kjøpt i perioden 1. november til 23. desember 2024. Les betingelsene her.
HF-P 158 TL-D III Spool Product Description: Product • Energy-efficient, electronic high-frequency ballast for TL-D fluorescent tubes Features and Benefits • Energy-efficient CELMA A2 • ENEC and CE approved in accordance with all relevant international safety and performance standards • Robust design for a lifetime of 50,000 hours at Tcmaxand over 60,000 on/off cycles on a light source. • Programmed, flicker-free preheated start (<1.6 sec.) allows the fluorescent tube to be turned on and off without reducing its lifespan (e.g., for use in combination with lighting control components) High power factor of 0.99 with THD <10% Automatic restart after voltage drop or fluorescent tube replacement Suitable for emergency DC operation at 186 V to 275 V (at 10 C), in line with IEC/EN60598-22 High-frequency operation alleviates eye strain caused by electromagnetic ballasts EMC compliant with EN55015:2006+A1:2007 The unit is protected against excessive mains voltage and incorrect connections Active power factor correction of constant light levels regardless of fluctuations in mains voltage Universal connector designed for horizontal manual and push-in robot cable routing as well as vertical ALF robot cable routing Application Ideal for applications where high energy efficiency is desired Used with motion detection control systems such as Philips OccuPlus In office buildings, hospitals, supermarkets, department stores and schools In Class I outdoor applications such as industrial plants and parking lots For emergency lighting purposes Technical Specifications Width (mm):30 Height (mm):28 Voltage(V):220-240 Length(mm):280
Ovenstående informasjon/spesifikasjoner er veiledende og kan uten varsel bli endret av produsenten. Det tas forbehold om trykkfeil og illustrerende bilder. Enkelte tekster kan være autogenerert eller maskinoversatt, så derfor kan det forekomme tekster som virker misvisende.