Instrumenter - Fluke tl175e test lead with 4mm adapters - 3565554
Varenummer: 2769248

Fluke tl175e test lead with 4mm adapters

Patented TwistGuardTM extendable tip shroud meets the highest electrical safety requirements to reduce tip exposure while providing the versatility needed for most measurementsNew WearGuardTM lead wire wear indication. Each test lead is covered by two layers of silicone insulation, inner contrasting color is exposed when the leads are nicked, scuffed, or otherwise damaged and in need of replacementDouble insulated silicone leads. TL175 test leads withstand high temperatures and remain flexible in cold temperatures.Extra-heavy duty strain relief on both probe-end and plug-end, tested beyond 30,000 bends without failure.Universal input plugs are compatible with all instruments that accept standard 4 mm shrouded banana plugsRatings: CAT II 1000 V, CAT III 1000 V, CAT IV 600 V, 10 A max., Pollution Degree 2TL175E also available. Includes removable 4 mm lantern tips that thread onto the lead tipProbes always show correct category rating for tip being usedEnvironmental ratings: -20 °C to 55 °C (-4 °F to 131 °F), altitude: 2000 m (6,562 ft)Conforms to EN61010-031

700,00 kr 560,00 kr eksl. mva
Rimeligste private frakt: 99,00 kr
Fjernlager, 2-4 dager til forsendelse

Fluke TL175E test lead with 4MM adapters Product description: Patented tip that can be extended and meets new electrical safety requirements for reducing sharp exposure while providing the versatility needed for most measurements. The length of the exposed probe tip can be changed from 3/4 (19 mm) to 4/25 (4 mm). New WearGuardTM indication of wear on wire. Each test lead is covered by two layers of silicone insulation. The inner contrasting color is exposed if the wires are cut, worn or otherwise damaged and need to be replaced. Double-insulated silicone wires. TL175 can withstand high temperatures and remain flexible at cold temperatures. Extra heavy-duty load protection both at the probe end and at the plug end has been tested to withstand 30,000 bends without failure.Universal plugs compatible with all instruments that can take standard 4mm encapsulated banana plugs.Classifications: CAT II 1000V, CAT III 1000V, CAT IV 600V, maximum current rating:10A,maximum pollution degree2.TL175E includes removable lantern tips for versatility.The probes always show the correct category classification for the used tip.Environmental classification:-20°Cto55°C,elevation2000m.Complies with EN61010-031 standard.One-year warranty

Produsent
Varenummer
2769248
Model
3565554
Ean
0095969528887
Produkttype
Testledning
Målekategori som støttes
CAT II, CAT III, CAT IV
Exposed probespiss lengde (min)
4 mm
Exposed probespiss lengde (maks)
1,9 cm
Sertifisering
EN61010-031
Kompatible produkter
Fluke 110 Plus, 113, 114, 115, 116, 117, 175, 177, 179 True RMS, 190-062/S, 190-102, 190-102/S, 190-104, 190-104/S, 190-202, 190-202/S, 190-204, 190-204/S, 190-504, 190-504/S, 233, 28 II Ex, 287, 289, 3000 FC GM, 3000 FC HVAC, 3000 FC IND, 3000 FC,323, 324, 345, 373, 381, 7 IV, FLK-A3000 FC Kit, FLK-A3001 FC Kit, CNX 3000 HVAC, CNX 3000 IND, CNX a3000, CNX v3000
Driftstemperatur (T-T)
-20 - 55 °C
Maksimal driftshøyde
2000 m

Egenskaper

Produkttype
Testledning
Målekategori som støttes
CAT II, CAT III, CAT IV
Exposed probespiss lengde (min)
4 mm
Exposed probespiss lengde (maks)
1,9 cm
Sertifisering
EN61010-031
Kompatible produkter
Fluke 110 Plus, 113, 114, 115, 116, 117, 175, 177, 179 True RMS, 190-062/S, 190-102, 190-102/S, 190-104, 190-104/S, 190-202, 190-202/S, 190-204, 190-204/S, 190-504, 190-504/S, 233, 28 II Ex, 287, 289, 3000 FC GM, 3000 FC HVAC, 3000 FC IND, 3000 FC,323, 324, 345, 373, 381, 7 IV, FLK-A3000 FC Kit, FLK-A3001 FC Kit, CNX 3000 HVAC, CNX 3000 IND, CNX a3000, CNX v3000

Miljømessige forhold

Driftstemperatur (T-T)
-20 - 55 °C
Maksimal driftshøyde
2000 m

Ovenstående informasjon/spesifikasjoner er veiledende og kan uten varsel bli endret av produsenten. Det tas forbehold om trykkfeil og illustrerende bilder. Enkelte tekster kan være autogenerert eller maskinoversatt, så derfor kan det forekomme tekster som virker misvisende.